中文English
科米瑞
首页联系我们
  1. 首页
  2. 产品中心
  3. 产品详情
科米瑞

© Copyright 科米瑞 2026

产品中心全量目录应用领域知识中心常见问题联系我们隐私政策桂ICP备2020008265号-5
广西科米瑞实验仪器设备有限公司13422079856122816084@qq.com
/Products/Washing-and-Sterilization-Equipment//autoclave-and-sterilizers//en-gb/autoclaves//en/products/科米瑞仪器应用领域实验室仪器选型

Analyze five elements in only one instrument

Analyze five elements in only one instrument

For the very first time it is possible to analyze the concentrations of carbon, sulfur, oxygen, nitrogen and hydrogen in metals and inorganic materials with only one analyzer. T...

品牌: Elementar价格: 面议服务区域: 全国

广西科米瑞实验仪器设备有限公司生产销售 Elementar Analyze five elements in only one instrument,可提供产品参数、报价和售后服务咨询,价格面议。

立即询价查看更多详情咨询该型号
← 返回产品列表
Analyze five elements in only one instrument

Analyze five elements in only one instrument For the very first time it is possible to analyze the concentrations of carbon, sulfur, oxygen, nitrogen and hydrogen in metals and inorganic materials with only one analyzer. The unique inductar ® EL cube is a completely new developed analyzer for highly precise and flexible determination of CS and ONH. It is equipped with a long-life solid-state high-frequency induction furnace, which makes it possible to reach sample temperatures of up to nearly 3,000 °C. Furthermore, the innovative technology makes tedious cleaning of oscillator tube and electrodes needless. All-in-one solution for CS/ONH analysis reduces investment costs and saves laboratory bench space while combining the best out of a CS and an ONH analyzer Precise results without tedious cleaning due to our innovative solid-state induction furnace technology to fulfill your analytical needs due to the customizable instrument concept that offers different modes, sample feeding options and detection options because of the intuitive software and the user-friendly instrument concept for daily routine operation For the very first time it is possible to analyze the concentrations of CS/ONH in inorganic materials such as metals or ceramics with only one analyzer . Based on our experience of more than 110 years in development and manufacturing of elemental analyzers, this innovative high-temperature CS/ONH analyzer was designed. The inductar EL cube is equipped with a solid-state induction furnace for both CS and ONH analysis, which makes it possible to analyze all five elements with a single analyzer. Investing in one innovative solution instead of two separate instruments saves costs and reduces the needed laboratory bench space massively. The inductar EL cube is best suited for research laboratories and universities or as a backup instrument for the inductar® CS cube and inductar® ONH cube standalone instruments. Precise results & reduced maintenance without tedious cleaning The innovative solid-state induction furnace brings the inductar EL cube to the next level. For the first time, it is technologically possible to use induction heating also for ONH analysis. By using smart instrument design and modern induction technology, the required temperatures of nearly up to 3,000 °C can be reached directly at the sample. Solid-state induction heating is in many respects advantageous for inorganic elemental analysis. The first advantage is obviously that no oscillator tube (CS) and electrodes (ONH) need to be frequently exchanged or cleaned, which results in less maintenance and more reliable results. Furthermore, the power and therewith the temperature can be smoothly controlled, which ensures best data quality. The customizable instrument concept of the inductar EL cube offers a wide range of customization options, suitable for your applicational needs. It combines all the advantages, both analytical and functional, of the stand-alone instruments inductar CS cube and inductar ONH cube in one single instrument. Furthermore, it offers different detection options. The new, innovative hydrogen sensor enables fast & simultaneous ONH determination, without having water in the system. The customizable concept is completed with different sample feeding options including manual samplers and a fully automated autosampler with up to 89 positions. The switch between the two modes CS and ONH is very easy and can be completed quickly by experienced users. The inductar EL cube is developed for unsurpassed user convenience and maximum robustness. The proprietary solid-state technology for the induction furnace ensures a virtually unlimited lifetime of components. Clearly arranged, easily accessible system components enable you to perform the few needed maintenance within seconds. The tool-free clamp connection system ensures a reliably leak tight instrument at any time. By design, no time-consuming cleaning operations are needed. The lifetime of used reagents is monitored by automated indicators. The intuitive, user friendly software offers not only the easy control the instrument, it also recognizes and prominently displays when maintenance work is needed. Therefore, the maintenance of the instrument is incredibly easy. The inductar EL cube has only very minimal operational requirements: Just 628 mm x 607 mm of your bench space in the laboratory, one standard electrical connection and only one gas supply are needed. The inductar EL cube does not need any compressed air in addition to the carrier gas, as the samplers are controlled and moved completely electronically. The long living solid-state induction furnace is highly energy efficient. It reduces power consumption and only needs minimal cooling. No external heat exchanger or connection to the tap water needed. The complete cooling cycle is built inside of the instrument. This makes it incredibly easy to place the inductar EL cube in your laboratory and saves bench space. The inductar EL cube is optimized for the determination of carbon, sulfur, oxygen, nitrogen and hydrogen. To switch between the two modes CS and ONH only some easy conversion steps need to be performed. The following modes are available: CS mode The CS mode offers simultaneous CS analysis with two wide-range infrared detectors (IR). ONH mode The ONH Mode offers simultaneous ONH determination. Oxygen is determined with a wide-range infrared detector (IR), nitrogen with a thermal conductivity detector (TCD) and hydrogen with our proprietary electronic hydrogen sensor (EHS). Furthermore, it offers the possibility to select from reduced modes to achieve the most flexibility: ON mode OH mode (H with TCD) H mode ONH mode The ONH Mode offers simultaneous ONH determination. Oxygen is determined with a wide-range infrared detector (IR), nitrogen with a thermal conductivity detector (TCD) and hydrogen with our proprietary electronic hydrogen sensor (EHS). Furthermore, it offers the possibility to select from reduced modes to achieve the most flexibility: Depending on the selected functionality, the inorganic sample that is to be analyzed will either be combusted in oxygen at above 2,000°C (CS) or melted in inert gas atmosphere at nearly up to 3,000°C (ONH). Subsequently, the resulting gases are analyzed, and all analysis is conducted according to international standards. Easy sample preparation and handling All kinds of solid samples are weighed into ceramic sample containers (sample mass up to 1 g). No sample preparation needed. Additional additives might be required, depending on the sample material. There is no need for special sample preparation, meaning all kinds of solid samples can be analyzed if they fit into the ELCAPS ONH nickel capsules and their height does not exceed the capsule’s height. Samples up to 1 g can be handled. For powder samples it is highly recommended to close the nickel capsules with our inPress tool. For some analyses, further additives may be needed.

相关产品

Advanced carbon and sulfur analysis of inorganic materials

Advanced carbon and sulfur analysis of inorganic materials

Advanced carbon and sulfur analysis of inorganic materials

Simultaneous ONH elemental analysis in metals and other inorganic materials

Simultaneous ONH elemental analysis in metals and other inorganic materials

Simultaneous ONH elemental analysis in metals and other inorganic materials

MAXimizing sample variety and throughput in nitrogen and protein determination

MAXimizing sample variety and throughput in nitrogen and protein determination

MAXimizing sample variety and throughput in nitrogen and protein determination

Lowest cost of ownership in nitrogen and protein determination

Lowest cost of ownership in nitrogen and protein determination

Lowest cost of ownership in nitrogen and protein determination

Optical emission spectrometer for precise metal testing. Anywhere. Anytime

提交需求

请填写必填信息,我们将在工作日尽快回复。

Optical emission spectrometer for precise metal testing. Anywhere. Anytime

Optical emission spectrometer for precise metal testing. Anywhere. Anytime

High precision carbon and sulfur analysis

High precision carbon and sulfur analysis

High precision carbon and sulfur analysis