UV500-Compact
规格参数。Parameter Standard range Other ranges on request / Typical Repeatability For low values ( UV254 0-200 Abs/m 0-600 Abs/m 0-2000 Abs/m / +/- 0.05 Abs/m +/- 0.15 Abs/m +/-
广西科米瑞实验仪器设备有限公司生产销售 HORIBA UV500-Compact,可提供产品参数、报价和售后服务咨询,价格面议。
← 返回产品列表
UV500-Compact
| Parameter | Standard range Other ranges on request / Typical Repeatability For low values (<10% FS) / Accuracy On standard solution |
|---|---|
| UV254 | 0-200 Abs/m 0-600 Abs/m 0-2000 Abs/m / +/- 0.05 Abs/m +/- 0.15 Abs/m +/- 0.5 Abs/m / +/- 2% |
| COD by UV correlation | 0-100 mg/l COD 0-2000 mg/l COD 0-20,000 mg/l COD / +/-0.05 mg/l COD +/- 1 mg/l COD +/- 10 mg/l COD / +/- 2% |
| BOD by UV correlation | 0-100 mg/l BOD 0-1000 mg/l BOD 0-10,000 mg/l BOD / +/-0.05 mg/l BOD +/- 0.5 mg/l BOD +/- 5 mg/l BOD / +/- 2% |
| TOC by UV correlation | 0-100 mg/l TOC 0-1000 mg/l TOC 0-10,000 mg/l TOC / +/-0.05 mg/l TOC +/- 0.5 mg/l TOC +/- 5 mg/l TOC / +/- 2% |
| Nitrate (NO3) | 0-100 mg/l NO3 / +/- 0.1 mg/l NO3 / +/- 2% |
| Colour | 0-100 Pt/Co 0-1000 Pt/Co / +/- 0.2 Pt/Co +/- 2 Pt/Co / +/- 2% |
| PAH (aromatics) | 0-10 mg/l C6H6 / +/- 0.01 mg/l C6H6 / +/- 2% |
| Oil in Water | 0-100 ppm OIW 0-1000 ppm OIW / +/- 0.1 ppm OIW +/- 1 ppm OIW / +/- 2% |
| Phosphate | 0-2 mg/l P-PO4 0-20 mg/l P-PO4 / +/- 0.01 mg/l P-PO4 +/- 0.1 mg/l P-PO4 / +/- 2% |
| Chromium IV | 0-2 mg/l Cr VI / +/-0.04 mg/l Cr VI / +/- 2% |
| Turbidity (TSS by correlation) | 0-10 NTU 0-100 NTU 0-1000 NTU / +/- 0.01 NTU +/- 0.1 NTU +/- 1 NTU / +/- 2% |
| pH | 0-14 pH / +/- 0.01 pH / +/- 2% |
| ORP | +/- 2000 mV / +/- 1 mV / +/- 2% |
| Dissolved Oxygen(DO) | 0-25 mg/l O2 / +/- 0.1 mg/l O2 / +/- 2% |
| Conductivity | 0-2000 μS / +/- 1 μS / +/- 2% |
| External turbidity (TSS by correlation) | 0-4 NTU 0-40 NTU 0-400 NTU / +/- 2% +/- 2% +/- 2% |
| External TSS | 0-1500 mg/l TSS 0-30000 mg/l TSS / +/- 1% of reading or +/- 2 mg/l TSS +/- 1% of reading or +/- 2 mg/l TSS |
| Temperature | 0-80°C / +/- 0.1 °C / +/- 2% |
| Sample flow | Recommended: 0 - 5 L/MIN |
| Sample pressure | 0 – 4 Bar (0 - 1 Bar with sampling peristaltic pump) |
| Sample temperature | 0 °C to 80 °C |
| Wet parts material | Quartz, Polypropylene, Polyethylene, FPM (Viton), PMMA |
| Measuring time | 5 sec (except PO4: 3 min) |
| Measurement interval | 1 min to 720 min Physicochemical parameters may be continuous |
| Memory | 5000 lines of measurements (up to 16 channels) with date and time |
| Consumption | Cleaning solution (5% sulfuric acid): 220 ml/day Reagent for PO4: 2 ml per measurement |
| Maintenance interval | Recommended: 6 months to 1 year (except for refilling) |
| Power supply | 90 - 264 VAC 50/60 Hz 80 VA |
| Screen | Colour TFT LCD 640x480 pixels with LED backlight |