中文English
科米瑞
首页联系我们
  1. 首页
  2. 产品中心
  3. 产品详情
科米瑞

© Copyright 科米瑞 2026

产品中心全量目录应用领域知识中心常见问题联系我们隐私政策桂ICP备2020008265号-5
广西科米瑞实验仪器设备有限公司13422079856122816084@qq.com
分析检测仪器生命科学仪器显微成像与光学样品前处理温控加热与制冷真空泵阀与流体科米瑞仪器应用领域实验室仪器选型

Spinsolve 80 MHz

Spinsolve 80 MHz

Magritek | The worlds leading high performance 80 MHz Benchtop NMR France-Belgium-Netherlands-Luxembourg joint Magnetic Resonance Conference,... Bordeaux Polymer Conference, Bor...

品牌: Magritek价格: 面议服务区域: 全国

广西科米瑞实验仪器设备有限公司生产销售 Magritek Spinsolve 80 MHz,可提供产品参数、报价和售后服务咨询,价格面议。

立即询价查看更多详情咨询该型号
← 返回产品列表
Spinsolve family benchtop NMR spectrometers

Magritek | The worlds leading high performance 80 MHz Benchtop NMR

France-Belgium-Netherlands-Luxembourg joint Magnetic Resonance Conference,...

Bordeaux Polymer Conference, Bordeaux, FR

Annual Meeting on Reaction Engineering...

Monitoring Chemical Reactions...

Optimized Performance combined with highest Versatility.

Optimum solvent suppression performance for samples in protonated solvents

Structure verification of Brucine

F on all systems + X nuclei for dual channel systems

Sensitivity: 280:1 (Single channel for 1% Ethyl Benzene)

Sensitivity: 200:1 (Dual channel for 1% Ethyl Benzene)

3D PFG gradients optimized for gradient-enhanced methods

Optional PFG gradients for diffusion spectroscopy (>0.5 T/m)

External Hardware Lock with no need for deuterated solvents

Suitable for on-line reaction monitoring

Compatible with automatic sample changer

Dimensions: 58 x 43 x 40 cm (23” x 17” x 16”)

Sensitivity measured in a single scan on a 1% ethylbenzene sample dissolved in deuterated chloroform. The signal used for the calculation is the one of the methylene group and the noise is calculated for a signal free region between the aromatic and the methylene signa

The best performance for online reaction monitoring

Metabolites produced by S. Cereviciae during Glucose Fermentation

processes like fermentations. The high sensitivity of

possible to detect metabolites produced at sub millimolar concentrations in just

minutes. In this particular example, solvent suppression

during the fermentation process. The residual water

possible to detect metabolites very close to the solvent

The Spinsolve 80 ULTRA device was used in combination with our reaction monitoring software package

to follow the course of a reaction on-line and also to determine its stereochemical outcome. As an example, the well-known Horner-Wadsworth-Emmons reaction (HWE reaction) was carried out and the result is

shown in the figure below. The HWE reaction was essentially developed to form the E-diastereoisomer as

the reaction product in favour of the corresponding Z-counterpart.

Spinsolve 80 MHz Spectra examples

Operating frequency: 80 MHz (1H)

Spinsolve 80: <0.35 Hz (50%) / <15 Hz (0.55%) / <30 Hz (0.11%)

Spinsolve 80 Ultra: <0.2 Hz (50 %) / <8 Hz (0.55%) / <16 Hz (0.11%)

(Single channel): >280:1 for 1% Ethyl Benzene

(dual channel): >200:1 for 1% Ethyl Benzene

相关产品

EFT-60

Eft-60 NMR Spectrometers

EFT-60

Eft-90 NMR Spectrometers

Eft-90 NMR Spectrometers

EFT-90

SC-1

SC-1 Robotic Sample Changer

SC-1

PHERAstar FSX

PHERAstar FSX

PHERAstar FSX

CLARIOstar Plus

CLARIOstar Plus

CLARIOstar Plus

VANTAstar

VANTAstar

VANTAstar

提交需求

请填写必填信息,我们将在工作日尽快回复。