Dual-Detector Super Range (DSR) Spectrometer Systems
Dual Detector Super Range (DSR) for measurements from 200-2,300nm Two instruments work as one updating spectral graph UV-VIS detector array plus NIR-InGaAs arrays
广西科米瑞实验仪器设备有限公司生产销售 StellarNet Dual-Detector Super Range (DSR) Spectrometer Systems,可提供产品参数、报价和售后服务咨询,价格面议。
← 返回产品列表
Dual Detector Super Range (DSR) for measurements from 200-2,300nm Two instruments work as one updating spectral graph UV-VIS detector array plus NIR-InGaAs arrays Options for up to 8 channels High Speed USB-2 interfaces Dual-DSR Spectrometer Overview Standard Configurations and Pricing BLUE-Wave-UVN + DWARF-Star with 200-1700nm range StellarNet Dual-Detector Super Range (DSR) spectrometer systems combine two instruments to cover the ultra violet, visible and near infrared portions of the electromagnetic spectrum. The two instruments work as one creating a unified spectral graph over the entire wavelength region, 200-2300nm. The two instruments employ both a UV-VIS detector array and NIR-InGaAs array in order to cover the entire range. 2048 element UV-VIS detector with the option of 512 or 1024 elements in the NIR. Various models allow for ranges from 200-1700, 280-1700, or 200-2300nm depending on the measurement specifications required. Like always StellarNet spectrometers are ruggedized for field or lab process measurements. A Miniature USB-Hub provides instrument PC interface. The Dual-DSR system has many applications for spectroradiometry, food and drug QA/QC, and chemical process measurements due to its ability to probe the near infrared while simultaneously measuring sample UV and color spectrum. Spectroradiometric Calibrations Optional IRRAD-CAL turns system into a SpectroRadiometer covering 200-1700nm Variety of accessories – reflectance probe/stand, transmission fixtures, and cuvettes for absorbance. Sample Color and Composition Measure sample CIELAB color and quantitative composition simultaneously Fast, easy results with little to no sample prep using reflectance fixture. These units are extremely ruggedized. The detector is bolted in position and military grade epoxy holds optics in place, making the instruments vibration tolerant, durable, and suitable for just about any lab and/or field measurement. A multi-band filter is integrated into the spectrograph to provide order sorting and prevent optical aliasing. The instruments optical input is attached via standard SMA-905 connector, using single strand fiber optic cable with typical silica core diameters of 400um, 600um, 1000um. Dual-DSR Instruments (Mix & Match your favorite UV-VIS + NIR spectrometers- some examples below) BLUE-Wave (VIS, CCD) plus DWARF-Star NIR-512 (InGaAs PDA) for 350-1700nm UVN-SR (UV-VIS-NIR, CCD) plus NIR-512 (InGaAs PDA) for 200-1700nm UVN-SR (UV-VIS-NIR, CCD) plus NIR-1024 (InGaAs PDA) for 200-1700nm DSR instruments listed below cannot be spectroradiometrically calibrated Concave grating (UV-VIS, CCD) plus NIRX-512 (InGaAs PDA) for 280-2300nm UVN-SR (UV-VIS-NIR, CCD) plus NIRX-512 (InGaAs PDA) for 200-2300nm UVN-SR (UV-VIS-NIR, CCD) plus NIRX-1024 (InGaAs PDA) for 200-2300nm Specifications BLUE-Wave Spectrometers from $ 2,700 Dynamic range: 2000:1 with 6 decades Dimensions: 1x3x5 inch = 25x75x125mm Optical resolution: see model table – to 0.2nm Detector type: CCD, 2k/3k pixels Power consumption: < 100 mA via USB port Detector range: 200-1100nm (<$350 extra) Interface: USB or USB Hub Pixel size: 14 x 200um or 7 x 200um Detector Integration: 1ms to 65s Diffraction Gratings: Holographic & Ruled
请填写必填信息,我们将在工作日尽快回复。