CS-600F

HORIBA

CS-600F 提供适合生产的更高级功能,如在各种应用中对高温化学药液进行在线测量的能力,减少停机时间的稳定运行,以及提高空间生产率的紧凑尺寸,以满足先进半导体湿法制程所需的准确化学药液浓度管理。

电话咨询这款仪器

微信扫码咨询

请发送仪器型号与应用需求,咨询选型及报价。

微信咨询二维码 13422079856
查看技术参数

根据您的样品与应用需求,咨询适用配置。

测量方法

产品概述与应用

产品说明

CS-600F 提供适合生产的更高级功能,如在各种应用中对高温化学药液进行在线测量的能力,减少停机时间的稳定运行,以及提高空间生产率的紧凑尺寸,以满足先进半导体湿法制程所需的准确化学药液浓度管理。

规格参数

Model CS-600F
Measurement principle Absorption spectroscopic method
Calculation principle Temperature compensation type multivariate analysis
Measurement target NH3/H2O2/H2O (reperesentative specification) * Please contact HORIBA regarding other chemicals.
Measurement range NH3:0.00~1.20mass%、H2O2:0.00~5.50mass%、H2O:93.3~100.0mass%
Repeatability NH3:±0.05mass%、H2O2:±10mass%、H2O:±1.0mass% Chemical temperature: Within ±1℃/1 hour
Sample solution temperature 20〜80℃
Measurement cycle Approx. 3 seconds
LCD display (1) Measured value (%) (2) Concentration alarm (HH/H/L/LL) (3) Error code (EXXX) (4) Chemical temperature (°C) (5) Serial/parallel communication status (P/S) (6) The times of background correction failure (CXXX)
Key input (1) Concentration alarm setting (HH/H/L/LL) (2) Concentration value shift (3) Background correction (4) Hot water correction (5) Temperature dependent concentration shift
Parallel input Input voltage of 12 V to 30 V DC by insulating with photo coupler (1) Parallel concentration alarm output (On/Off) (2) Switching chemical solution for measurement (including background correction) (3) Hot water correction
Parallel output Transistor output (NPN open collector) by insulating with photo coupler Maximum current when powered ON: 5 mA DC (no internal protective resistance) Maximum voltage when powered OFF: 30 V DC (1) Concentration alarm (ON at HH/H/L/LL alarm) (2) Monitor error (OFF at error) (3) Measuring (ON at measurement) (4) Chemical solution type for measurement (5) Echo to hot water correction input (6) Warning (ON at occurred) (7) Background correction status 8) Hot water correction status
Serial input RS-232C (1) Request for readout of measurement data (2) Select chemical solution type to be measured (3) Hot water correction
Serial output RS-232C (1) Measured data No. (2) Chemical solution type (3) Concentration value (4) Error code (5) Chemical temperature
Analog output 4 mA to 20 mA In case of monitor error occurs, measurement is stopped or invalid chemical range is selected, the signal output is fixed at 1.5 mA. The load resistor must be 500 Ω maximum.
Chemical solution temperature input Terminal block inlet (terminal screw M3) Platinum resistance temperature sensor: Pt100 (Three-conductor type, Class A) *Temperature sensor is not included.
Air (for operation and purge) Connection port: 4 mm O.D. quick joint, Pressure: 0.2 MPa ±0.02 Mpa
Power source 100~230V AC(Single-Phase)、50/60Hz
Power consumption Approx. 85 VA (transient electric current at the time of the start is excluded)
Weight (Monitor) Approx. 3.6 kg (Lamp unit) Approx. 2.8 kg (Sample cell) Approx. 1.2 kg
Ambient temperature (Monitor, Lamp unit) 20°C to 30°C (Sample cell, Optical fiber) 20°C to 35°C (Sudden temperature change should be avoided, within ±1°C/1 hour)
Ambient humidity (Monitor, Lamp unit, Sample cell) 40% to 70% (Should be no dew condensation)
Slanting angle at installation (Monitor, Lamp unit) within ±1°
Optical fiber Length: 5 m, minimum bend radius: R 150 mm
技术概览

技术参数

品牌HORIBA
型号/名称CS-600F
ModelCS-600F
Measurement principleAbsorption spectroscopic method
Calculation principleTemperature compensation type multivariate analysis
Measurement targetNH3/H2O2/H2O (reperesentative specification) * Please contact HORIBA regarding other chemicals.
Measurement rangeNH3:0.00~1.20mass%、H2O2:0.00~5.50mass%、H2O:93.3~100.0mass%
RepeatabilityNH3:±0.05mass%、H2O2:±10mass%、H2O:±1.0mass% Chemical temperature: Within ±1℃/1 hour
Sample solution temperature20〜80℃
Measurement cycleApprox. 3 seconds
LCD display(1) Measured value (%) (2) Concentration alarm (HH/H/L/LL) (3) Error code (EXXX) (4) Chemical temperature (°C) (5) Serial/parallel communication status (P/S) (6) The times of background correction failure (CXXX)
Key input(1) Concentration alarm setting (HH/H/L/LL) (2) Concentration value shift (3) Background correction (4) Hot water correction (5) Temperature dependent concentration shift
Parallel inputInput voltage of 12 V to 30 V DC by insulating with photo coupler (1) Parallel concentration alarm output (On/Off) (2) Switching chemical solution for measurement (including background correction) (3) Hot water correction
Parallel outputTransistor output (NPN open collector) by insulating with photo coupler Maximum current when powered ON: 5 mA DC (no internal protective resistance) Maximum voltage when powered OFF: 30 V DC (1) Concentration alarm (ON at HH/H/L/LL alarm) …