HC-200CA HC-200CA
产品与应用图片。
实验室仪器

HC-200CA

HORIBA

Contributes to chemical control in the wastewater treatment process by continuously monitoring calcium ion concentration in the tank. Running costs and risk of scale generation are reduced by optimizing chemical usage, thereby contributing to stable...

电话咨询这款仪器

微信扫码咨询

请发送仪器型号与应用需求,咨询选型及报价。

微信咨询二维码 13422079856
查看技术参数

根据您的样品与应用需求,咨询适用配置。

测量方法

产品概述与应用

产品说明

Contributes to chemical control in the wastewater treatment process by continuously monitoring calcium ion concentration in the tank. Running costs and risk of scale generation are reduced by optimizing chemical usage, thereby contributing to stable...

规格参数

Transmitter model HC-200CA
Sensor model CA-2000:Calcium ion sensor
Sensor chip model 7695: Calcium ion chip, 7211: Reference chip
Measurement range Calcium ion concentration:10 to 4000 mg/L (display range: 0 to 4000 mg/L) Temperature:0 to 40 °C (display range: -10 to 110 °C)
Measurement conditions pH:5 to 11
Sample Water in top clear layer of CaF2 sedimentation tank in fluoride acid wastewater treatment of semiconductor manufacturing facility.
Concentration Ca2+:200 to 600 mg/L, SO42-:200 to 700 mg/L, pH:5 to 11
Temperature 25 to 40 °C
Conductivity 10 to 20 mS/cm
Available range options 100.0, 1000, 4000 mg/L
Display resolution Calcium ion concentration:0.1 mg/L: 0.0 to 100.0 mg/L, 1 mg/L: 0 to 1000 mg/L, 10 mg/L: 0 to 4000 mg/L ※It depends on the set range. Temperature:0.1 °C
Repeatability Calcium ion concentration:±10% of reading (standard solution) Temperature:±0.3 °C (equivalent input)
Temperature compensation Compatible temperature element:Platinum resistor: 1 kΩ (0 °C) Temperature measurement range:0 to 40 °C Temperature calibration:1 point calibration for comparison with the reference thermometer
Calibration Standard solution calibration (2 points) Select 1 to 10 mg/L, 10 to 100 mg/L, or 100 to 1000 mg/L
Adjustment Sample adjustment using manual analysis (1 point), standard curve input function (linear function)
Self-check Calibration error, sensor diagnosis error, transmitter error
Transmission output 3 points 4 to 20 mA DC, input/output isolation type Maximum load resistance 900 Ω Output1:Calcium ion concentration: Arbitrary setting within the measurement range is possible. Output2:Temperature: Arbitrary setting within the range from -10 to 110 °C is possible. Error output:Provided with burnout function (selectable from 3.8 mA and 21 mA for setting) Hold function:Selectable from the latest value hold and the preset value hold
Contact output 3 points No-voltage contact output Relay contact, SPST (1a), SPDT (1c) Signal R1, R2:Selectable from among the upper limit alarm, lower limit alarm, during transmission output hold, and cleaning output (closed at alarm operation, open under normal conditions and in a power-off state) FAIL:Error alarms for values outside the measurement range and self-check output can be set. Delay time: 0 to 600 seconds
Cleaning output 1 point Voltage contact output (connection power supply voltage output) Relay contact, SPDT (1a) Contact function:Solenoid valve for cleaning control
Contact input 1 point No-voltage "a" contact for open collector Contact function:Select from the external input of the cleaning operation and HOLD input transmission output
Communication function RS-485 2 wire system, isolated from the input circuit Not isolated from transmission circuit
Operation temperature range -20 to 55 °C (no freezing)
Power supply Rated power supply voltage:AC 100 to 240 V ±10% 50/60 Hz, Power consumption:25 VA(max)
Structure Protection class:IP65, Installation method:50 A pole-mounted or wall-mounted, Material of case:Aluminum alloy, Material of hood and the mounting brackets:SUS304
Mass Main frame:Approx. 3.5 kg Hood,mounting bracket: Approx. 1 kg
Compliance standard CE marking, FCC Rules
Sensor unit model CA-2000
Sample condition 0 to 40 °C (no freezing)
Measurement depth 0 to 10 m
Wetted material SUS316, FKM, PVC
技术概览

技术参数

品牌HORIBA
型号/名称HC-200CA
Transmitter modelHC-200CA
Sensor modelCA-2000:Calcium ion sensor
Sensor chip model7695: Calcium ion chip, 7211: Reference chip
Measurement rangeCalcium ion concentration:10 to 4000 mg/L (display range: 0 to 4000 mg/L) Temperature:0 to 40 °C (display range: -10 to 110 °C)
Measurement conditionspH:5 to 11
SampleWater in top clear layer of CaF2 sedimentation tank in fluoride acid wastewater treatment of semiconductor manufacturing facility.
ConcentrationCa2+:200 to 600 mg/L, SO42-:200 to 700 mg/L, pH:5 to 11
Temperature25 to 40 °C
Conductivity10 to 20 mS/cm
Available range options100.0, 1000, 4000 mg/L
Display resolutionCalcium ion concentration:0.1 mg/L: 0.0 to 100.0 mg/L, 1 mg/L: 0 to 1000 mg/L, 10 mg/L: 0 to 4000 mg/L ※It depends on the set range. Temperature:0.1 °C
RepeatabilityCalcium ion concentration:±10% of reading (standard solution) Temperature:±0.3 °C (equivalent input)