中文English
科米瑞
首页联系我们
  1. 首页
  2. 产品中心
  3. 产品详情
科米瑞

© Copyright 科米瑞 2026

产品中心全量目录应用领域知识中心常见问题联系我们隐私政策桂ICP备2020008265号-5
广西科米瑞实验仪器设备有限公司13422079856122816084@qq.com
分析检测仪器生命科学仪器显微成像与光学样品前处理温控加热与制冷真空泵阀与流体科米瑞仪器应用领域实验室仪器选型

Fully integrated TOC/TN b isotope ratio analysis

Fully integrated TOC/TN b isotope ratio analysis

Stable isotope analysis helps to understand the processes that control the carbon and nitrogen cycling in aquatic systems. The quantitative and isotopic analysis of dissolved ma...

品牌: Elementar价格: 面议服务区域: 全国

广西科米瑞实验仪器设备有限公司生产销售 Elementar Fully integrated TOC/TN b isotope ratio analysis,可提供产品参数、报价和售后服务咨询,价格面议。

立即询价查看更多详情咨询该型号
← 返回产品列表
Fully integrated TOC/TN b isotope ratio analysis

Fully integrated TOC/TN b isotope ratio analysis Stable isotope analysis helps to understand the processes that control the carbon and nitrogen cycling in aquatic systems. The quantitative and isotopic analysis of dissolved matter (e.g. dissolved total organic carbon, total bound nitrogen, etc.) is of particular importance since this pool is a prime conduit in the cycling of nitrogen and carbon. The iso TOC cube elemental analyzer inlet presents a new high-temperature combustion method for the quantitative and isotopic analysis of dissolved total organic carbon (TOC) and dissolved total bound nitrogen (TN b ). It is the only instrument capable of performing these analyses, making it an indispensable tool for ecologists, limnologists, and oceanographers. Direct δ 13 C isotope analysis of TOC in aqueous samples with the possibility of column preconcentration for low TOC samples Direct δ 15 N isotope analysis of TN b in aqueous samples with the only commercially available instrument capable of this kind of analysis thanks to a direct analysis method which does not require sample preparation The iso TOC cube is a combustion analyzer with greater analytical robustness and less maintenance than analyzers working with wet-chemical or UV oxidation methods. Even when analyzing refractory organic substances such as humic acids or lignin, which are traditionally difficult to combust, you can expect reliable, matrix-independent measurement results thanks to the complete conversion of all compounds at these high combustion temperatures. Thus, the iso TOC cube enables dissolved carbon and nitrogen isotope ratio analysis with highest precision and accuracy in all types of liquids, from drinking water or industrial wastewater up to soil leachates, suspensions, brines, or marine samples. For low TOC samples the iso TOC can be configured with an optional column, which preconcentrates TOC. The one and only analyzer for direct δ 15 N isotope analysis of TN b in aqueous samples The iso TOC cube elemental analyzer for EA-IRMS is the only commercially available instrument capable of simultaneous isotope ratio analysis of dissolved total organic carbon (TOC) and dissolved total bound nitrogen (TNb) in aqueous samples. For the δ 15 N analysis of TN b , the iso TOC cube uses our unique Low Concentration Module (LCM) and an integrated membrane degasser for removing dissolved N 2 , increasing sample detection levels. The LCM uses cryogen-free, thermoelectric cooling combined with our Advanced Purge and Trap (APT) separation technology to achieve TNb detection levels of 25 ppm. High sample throughput thanks to direct analysis method By performing direct analysis on the sample, the need for laborious pre-preparation of samples is removed. The direct determination of dissolved carbon and nitrogen out of the liquid phase ensures complete quantitative conversion of all compounds, so that offline sample preparation through freeze drying can be omitted. Designed for unattended 24/7 analysis, iso TOC cube offers highest sample throughput. High system uptime thanks to low-maintenance design The iso TOC cube features a 32 position autosampler, which is reloadable at any time. Whenever maintenance is necessary, our user-friendly clamp connections ensure a tool-free experience, while the slide-out furnace guarantees easy accessibility and a comfortable working posture. Future-proof thanks to 10 years guarantee Thanks to the outstanding robustness and longevity of our iso TOC cube, we grant a 10-year guarantee on the high-temperature combustion furnace. With our long-term oriented dedication to technical support, we provide spare parts for a minimum of 10 years. This results in outstanding low total cost of ownership, giving you confidence in return of investment. The iso TOC cube is optimized for the analysis of: of Total Organic Carbon (TOC), Total Inorganic Carbon (TIC), and Total Bound Nitrogen (TN b )* Volume injections up to 3 ml for optimal detection. Large detection range From 5 ppm to 60,000 ppm dissolved carbon, 25 ppm to 60,000 ppm for dissolved nitrogen*. Elemental performance (external precision, 1σ): C: < 2 % relative N*: < 2 % relative Isotope ratio performance (external precision, 1σ): δ 13 C: 0.1 ‰ δ 15 N*: 0.2 ‰ ~ 5 min in C mode ~ 15-20 min in CN mode* Depending on sample type, analysis mode, and configuration. High-temperature combustion unit Quantitative sample digestion in the presence of oxygen at 950 °C - with a 10-year furnace warranty. Optional preconcentration column for CO 2 and N 2 with the low concentration module. Carbon dioxide specific high sensitivity infrared detector (both stand-alone and IRMS mode) Nitrogen monoxide specific high sensitivity infrared detector (only stand-alone mode)* Sample introduction via freely adjustable syringe injection with bubble elimination feature and integrated liquid autosampler with 32 or 50* positions, reloadable during analysis. With automatic acidification and sparging. 1,200 °C (standard operating temperature: 950 °C) Windows® based lyticOS® Software Suite with LIMS integration and auto sleep and wake-up function for automated and unattended overnight operation. Module 1: 48 x 63 x 82 cm (W x D x H, including sampling turret) Module 2*: 27 x 62 x 53 cm (W x D x H) Balance and elemental analyzer form a system. We offer analytical balances from the leading manufacturers with our instruments. Please contact us for further information. Optional device for the pre-concentration of N 2 and CO 2 after combustion. The LCM provides cryogen-free, thermoelectric cooling to the Advanced Purge and Trap (APT) separation column, allowing sub-ambient temperatures leading to excellent chromatography.

相关产品

Advanced carbon and sulfur analysis of inorganic materials

Advanced carbon and sulfur analysis of inorganic materials

Advanced carbon and sulfur analysis of inorganic materials

Analyze five elements in only one instrument

Analyze five elements in only one instrument

Analyze five elements in only one instrument

Simultaneous ONH elemental analysis in metals and other inorganic materials

Simultaneous ONH elemental analysis in metals and other inorganic materials

Simultaneous ONH elemental analysis in metals and other inorganic materials

MAXimizing sample variety and throughput in nitrogen and protein determination

MAXimizing sample variety and throughput in nitrogen and protein determination

MAXimizing sample variety and throughput in nitrogen and protein determination

Lowest cost of ownership in nitrogen and protein determination

Lowest cost of ownership in nitrogen and protein determination

提交需求

请填写必填信息,我们将在工作日尽快回复。

Lowest cost of ownership in nitrogen and protein determination

Optical emission spectrometer for precise metal testing. Anywhere. Anytime

Optical emission spectrometer for precise metal testing. Anywhere. Anytime

Optical emission spectrometer for precise metal testing. Anywhere. Anytime