The very best in ppb analysis
Meet the most sensitive combustion analyzer for sulfur and nitrogen in diesel, gasoline, and related samples: the trace SN cube. This sulfur and nitrogen analyzer with its catal...
广西科米瑞实验仪器设备有限公司生产销售 Elementar The very best in ppb analysis,可提供产品参数、报价和售后服务咨询,价格面议。
← 返回产品列表
Meet the most sensitive combustion analyzer for sulfur and nitrogen in diesel, gasoline, and related samples: the trace SN cube. This sulfur and nitrogen analyzer with its catalyst-supported combustion technology ensures complete decomposition of all kinds of samples without soot formation and delivers fast analysis results in just a few minutes. By incorporating two complete combustion and detection channels for sulfur and nitrogen, respectively, into one analyzer, the trace SN cube works as two analyzers in one box. This concept allows the specific optimization of the determination for each element. This ensures sulfur and nitrogen analysis with highest precision and accuracy. The analyzer combines highest analytical performance with speed, flexibility, and long-term stability in automated operation. The most sensitive sulfur and nitrogen determination with detection limits of 6 ppb for sulfur and 15 ppb for nitrogen for reliable results and maintenance-friendly instrument operation simplifies daily routine with a low-maintenance design Optionally available modules allow the analysis of solids, gases, liquefied petroleum gas (LPG), or chlorine The most sensitive S and N determination thanks to two-channel system The trace SN cube has an integrated two-channel system with two independent furnaces and combustion tubes, which makes it possible to adjust all parameters (temperature, injection volume, injection speed, etc.) for optimal sulfur and nitrogen determination with highest precision and accuracy. Samples are injected directly into the combustion tubes by the integrated 50 or 56 (temperature controllable)-position autosampler. The highly sensitive UV fluorescence and chemiluminescence detectors guarantee utmost sensitivity with detection limits of 6 ppb for sulfur and 15 ppb for nitrogen. This ultra-trace detection power gives rise to uncompromised sulfur and nitrogen analysis even in samples of lowest concentrations, and the two analyzers in one box design results in significant cost and space savings compared to the purchase of two separate analyzers. Soot-free combustion for reliable results and low maintenance In high-temperature combustion of oil and petrochemical samples, a well-known problem is soot formation caused by incomplete combustion. This affects data quality and also results in higher maintenance efforts. The trace SN cube successfully avoids soot formation by performing a catalyst-supported combustion, using especially developed catalysts which drastically optimize the oxidation process. With this technique, almost any sample can be ignited without soot production at injection volumes up to 80 μl, ensuring reliable results in any kind of sample and keeping maintenance as low as possible. The trace SN offers outstanding sample flexibility. Apart from liquid injections with the integrated 50 (not temperature controllable) or 56 (temperature controllable)-position autosampler, the analyzer can be equipped with an optional gas, LPG, or solids module for highest versatility in your sample matrices. For the analysis of highly volatile samples we recommend the use of our temperature-controllable autosampler. Retrofitting is easily done within a few minutes. Future-proof thanks to 10 years guarantee Thanks to the outstanding robustness and longevity of our trace SN cube, we grant a 10-year guarantee on the high-temperature combustion furnace. With our long-term oriented dedication to technical support, we provide spare parts for a minimum of 10 years. This results in outstanding low total cost of ownership, giving you confidence in return of investment. The trace SN cube is optimized for the analysis of: Injection volume free adjustable from 3-80 µl Large measuring range: S: up to 1,000 ppm, 6 ppb LOD N: up to 1,000 ppm, 15 ppb LOD < 2 % rel. for 10 ppm standard (S and N) ~ 4-6 min per parameter, self-optimizing according to element content and sample weight. Depending on sample type, analysis mode, and configuration. The trace SN cube offers high-temperature combustion in the carrier gas at up to 1,150 °C, with direct injection of liquid samples into separate ports for N and S determination. High sensitive UV-F and CL detector, linear over entire range Integrated 50* positions autosampler (not temperature controllable) for liquids Integrated 56* positions autosampler (temperature controllable) for liquids Integrated 80* or 120* positions autosampler for solids Windows ® based trace SN cube operating software with LIMS integration and auto sleep and wake-up function for automated and unattended overnight operation. 21 CFR Part 11 functionality available.* Synthetic air, argon, oxygen for N Synthetic air for S 47 × 55 × 57 (W × D × H) without detectors, autosampler Balance and elemental analyzer form a system. We offer analytical balances from the leading manufacturers with our instruments. Please contact us for further information. We offer a variety of SN standards dissolved toluene with concentrations from 1 µg/ml up to 1,000 µg/ml.
请填写必填信息,我们将在工作日尽快回复。